HVAC
MITSUBISHI MR.SLIM ductless multi-zone system: units and wall mounted thermostats locations (3D)
ERV / WHOLE HOUSE DEHUMIDIFIER
Units, ducting and ports locations
HVAC
MITSUBISHI MR.SLIM ductless multi-zone system: units and wall mounted thermostats locations
ERV, DEHUMIDIFIER PORTS LOCATIONS
HVAC INDOOR UNITS
MITSUBISHI MSZ-GL12NA-U1, MSZ-GL09NA-U1, SZ-GL06NA-U1
HVAC WALL MOUNTED CONTROLLER
MITSUBISHI kumo touch™ WIRELESS CONTROLLER
Model: MHK2
Note: "kumo cloud" will NOT be set up, so use RedLINK™ Wireless Receiver
Model: MHK2
Note: "kumo cloud" will NOT be set up, so use RedLINK™ Wireless Receiver
CONDENSATE PUMP
ASPEN Silent+ Mini Aqua; Model #: FP3332/RS
Max. flow @ 0 head: 2.9 US Gal/h / 11L/h; Max. rec. head: 23ft / 7m; Max. suction lift: 6.5ft / 2m
dB(A) @ 3ft / 1m: 19
Installed inside the unit with acoustic damper & anti vibration
bracket
Max. flow @ 0 head: 2.9 US Gal/h / 11L/h; Max. rec. head: 23ft / 7m; Max. suction lift: 6.5ft / 2m
dB(A) @ 3ft / 1m: 19
Installed inside the unit with acoustic damper & anti vibration
bracket
CONDENSATE PUMP (MASTER BEDROOM UNIT)
ASPEN Silent+ Mini Orange: Model #: FP3318/RS
Max. flow @ 0 head: 2.9 US Gal/h / 11L/h; Max. rec. head: 23ft / 7m; Max. suction lift: 6.5ft / 2m
dB(A) @ 3ft / 1m: 19
Installed remotely, above the unit, in the attic
Max. flow @ 0 head: 2.9 US Gal/h / 11L/h; Max. rec. head: 23ft / 7m; Max. suction lift: 6.5ft / 2m
dB(A) @ 3ft / 1m: 19
Installed remotely, above the unit, in the attic
ERV UNIT
Zehnder ComfoAir Q350 TR
Note: LEFT orientation unit must be used, as per ERV / WHOLE HOUSE DEHUMIDIFIER drawing
Note: LEFT orientation unit must be used, as per ERV / WHOLE HOUSE DEHUMIDIFIER drawing
ERV WALL MOUNTED CONTROLLER
Zehnder ComfoSense C67
ERV DUCT COMPONENTS
Zehnder ComfoWell 520
Attenuator (Silencer), Filter Housing and Manifold Box
Note: all 3 components must be used in fresh air supply direction, attenuator and manifold box must be used in exhaust direction, with CW-P 520 – DN 150 end plate (150 mm (5.9') connection for 6" conventional metal duct), as per ERV drawing
Attenuator (Silencer), Filter Housing and Manifold Box
Note: all 3 components must be used in fresh air supply direction, attenuator and manifold box must be used in exhaust direction, with CW-P 520 – DN 150 end plate (150 mm (5.9') connection for 6" conventional metal duct), as per ERV drawing
ERV FRESH AIR DISTRIBUTION DUCTING
Zehnder ComfoTube 75
Flexible air distribution pipe (inside Ø: 2.5", outside Ø: 3"), outside ribbed, inside smooth, medical grade HDPE
Flexible air distribution pipe (inside Ø: 2.5", outside Ø: 3"), outside ribbed, inside smooth, medical grade HDPE
ERV FRESH AIR DISTRIBUTION DUCTING (OPTION 2)
Zehnder ComfoFlex
Underwriters Laboratories (UL) listed as Class 1 air duct, Standard 181.
NOTE: Use one instead of Zehnder ComfoTube only if UL listing is required by the local code
Underwriters Laboratories (UL) listed as Class 1 air duct, Standard 181.
NOTE: Use one instead of Zehnder ComfoTube only if UL listing is required by the local code
ERV DUCTING
Zehnder ComfoPipe
Compact Pipe 160, inside Ø: 6.3″ (160mm), outside Ø: 7.48" (190mm)
Compact Pipe 160, inside Ø: 6.3″ (160mm), outside Ø: 7.48" (190mm)
ERV SUPPLY AND EXTRACT AIR VALVES
Zehnder ComfoValve Luna S / E
ERV EXTERIOR GRILLE
Zehnder External Wall Grille 6.3" (160mm)
ERV ROUND BOOT
Zehnder America RND-2T, RND-3T Round Boot
Technical Specification
Technical Specification
ERV ROUND BOOT INSTALLATION MANUAL
DEHUMIDIFIER UNIT
Santa Fe Ultra120
10" Return Air Inlet, 10" Supply Air Outlet
10" Return Air Inlet, 10" Supply Air Outlet
DEHUMIDIFIER WALL MOUNTED CONTROLLER
Ultra-Aire DEH 3000
DEHUMIDIFIER SUPPLY GRILLE
Fantech MG Metal Supply Grille 5" Duct
Model: MGS5
Model: MGS5
DEHUMIDIFIER RETURN GRILLE (SAMPLE)
8" x 8" Duct Opening Steel Return Air Filter (8" x 8" x 1" MERV 8/11) Grille
10.75" Width X 10.75" Height
10.75" Width X 10.75" Height
DEHUMIDIFIER DUCTING SILENCER (SAMPLE)
ALAN MANUFACTURING Air Duct Silencers
Building Code Compliant - Meets NFPA Standards 90A & 90B
UL Listed - Class I Air Duct
Building Code Compliant - Meets NFPA Standards 90A & 90B
UL Listed - Class I Air Duct
Bath Exhaust Fan
Tech Drive Super-Quiet 70 CFM, 0.3 Sone (Fan Sound Level)
Housing Size: 9" x 9" x 7.6" with 4" duct, ceiling mounting opening: 9.4" x 9.4"
Housing Size: 9" x 9" x 7.6" with 4" duct, ceiling mounting opening: 9.4" x 9.4"
Bath Exhaust Fan (OPTION 2)
PANASONIC Whisper Fit EZ Quiet 80 or 110 CFM Ceiling Low Profile Dual Speed
Model #FV-08-11VF5
Note: must be set to 80 CFM - 0.3 Sones (Fan Sound Level)
Model #FV-08-11VF5
Note: must be set to 80 CFM - 0.3 Sones (Fan Sound Level)
WORKSHOP COMPACT DEHUMIDIFIER (FUTURE PROJECT)
Santa Fe Compact70
Note: will be installed after construction is complete, as the whole house dehumidifier doesn't circulate air in the workshop
Note: will be installed after construction is complete, as the whole house dehumidifier doesn't circulate air in the workshop